Description
ARCODE
MODELS |
5,5 KW (14A), 7,5 KW (17A), 11 KW (26A), 15 KW (35A), 22 KW (50A), 35 KW (75A) |
COMPLIANCE WITH STANDARDS |
EN 81-20 |
ENGINE CONTROL |
SYNCHRON AND ASYNCHRONOUS MACHINE |
ENCODER OPTIONS |
5V TTL, 10-30V HTL, EnDAT, SSl, SinCos, BlSS |
INPUT VOLTAGE |
AC 3 PH, 320-420V, 50/60 HZ |
COMMUNICATION PROTOCOL |
CANbus |
CONTROL TYPE |
SINGLE BUTTON AND DOUBLE BUTTON COLLECTION |
GROUP CONTROLLER |
UP TO 8 ELEVATORS |
STATION |
UP TO 64 STOPS |
SPEED |
UP TO 4 M/S |
STARTING HOLD |
PRE-TORQUE AND START-HOLD FUNCTIONS TO PREVENT SLIP-BACK AT STARTING |
DIRECT STOP |
PERFECT COMFORT THANKS TO DIRECT STOP |
DOOR CONTROL |
SINGLE INPUT, DOUBLE INPUT |
> Connection with cabinet units
Serial cabin communication via CANbus line Between control panel and revision box
One-to-one connection with plug-in flat cable Plug-in between cabin button and inspection box
one-cable plug-in connection
> Connection with floor units
Serial floor communication via CANbus line or parallel floor connection with MSP16 card.
Additive, well CANbus line with plug-in cables from floor to floor, extending throughout the entire well
Pluggable connection with plug-in cable attached to the well CANbus line for each floor for floor buttons
> Compact inspection panel on cabinet
Easy to use mobile device with 2 meters long hand terminal device
> Door contacts connection
Door contact installation with plug-in cables extending from floor to floor, extending all along the shaft
Connection with socket cables attached to the door contact system on each floor for the plug-lock contacts of the landing doors.
> Pit installation
Socket connection via a single cable with the bottom of the pit box and mobile and easy use with the hand terminal
> Cab position information
With encoder system With magnetic switch and magnets
> Cable coding
Fast fault resolution thanks to the cable labeled with colors and texts
> Automatic door control
All kinds of automatic door control Independent door control according to the stops with double door support
1 door control inputs-outputs in the inspection box and 2 in the control panel
> Auto floor
With 1 phase 220VAC UPS or battery group connection Easy direction or to the desired floor
> Door bridging
Door early opening and door open level renewal with door bridging circuit on DBR card
>Programmable I/O
Freely programmable inputs and outputs on the motherboard, cabin cards and floor cards
> Test functions
Special test function for testing car and landing button connections
> Remote control
Ability to control ARCODE from any point with the hand terminal connected to the CANbus line
> Cabin-well feeding circuits
Residual current protected cabin and well supply fuses
> Emergency alarm
Emergency alarm siren (with buttons from the top of the cabin and the bottom of the well)
> Safety circuit connections
Special connections for safety circuits in control panel, inspection box and pit box
> Eligibility
Full compliance with EN 81-20 standards as a complete elevator control system with EMC test report